Menu

Varian

Ref : 1770207-18-CP
Condition : Used
Manufacturer : Varian
Model : -
Short Description : -
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)
Last check : 12 Feb. 2020

Varian 3800 GC with FID, ECD, TCD & NCT

Specifications



Dimensions and Weights

-Size: 53 cm (h) x 66 cm (w) x 56 cm (d)

- Weight: 43 kg



Environmental Conditions

-Operating temperatures: 10°C to 40°C

-Operating humidity (relative): 5% to 95%

-Line voltage requirements: 101V, 120V, 230V (±10% nominal)



Column Oven

-Dimensions: 28 cm (w) x 20 cm (d) x 28 cm (h)

-Temperature range: ambient +4 °C to 450 °C

-With liquid N2: -99 °C to 450 °C

-With liquid CO2: -65 °C to 450 °C

-Temperature program ramps/holds: 7/8

-Maximum temperature ramp rate: 100 °C/min for all voltages

-Cool down rate: 400 °C to 50 °C in 4.5minutes

-Temperature set-point resolution: 1 °C



Injector Options

-Maximum injectors: three operating concurrently

-Pneumatics: manual or electronic flow control (EFC)

-Columns: capillary columns standard with optional packed column adapter

-Injectors

-CP-1177Split/Splitless

-1079 Programmable Temperature Vaporizing (PTV)

-1061 Flash Megabore/Packed

-1041 On-Column Megabore/Packed


CP-1177 Split/Splitless

-Pressure range: 0-100 psi

-Total flow: 500 rrillrnin at 10 psi

-Maximum temperature: 450 °C

-Split range: 1-10,000 (column dependent)


1079 Programmable Temperature Vaporizing (PTV)

-Pressure range: 0-100 psi

-Total flow: 500 mL/min at 10 psi

-Temperature range

- -99 °C to 450°C liquid N2

- -65 °C to 450°C liquid CO2

-Maximum temperature ramp rate: 180 °C/min

-Temperature ramps: 4

-Split range: 1-10,000 (column dependent)

- Operational modes

- Temperature ramped splitless

- Coldon-column

- Large Volurne Injection

- Split and splitless

- ChromatoProbe solid sample introduction:

optional


1061 Flash Megabore/Packed

-Pressure range: 0-100 psi

-Total Flow: 50 mL/min (Type 3 EFC)

500mL/min (Type 4 EFC)

-Maximum temperature: 450 °C


1041 On-Column Megabore/Packed

-Pressure range: 0-100 psi

-Total Flow: 50 mL/min (Type 3 EFC)

500mL/min (Type 4 EFC)

-Maximum temperature: 450 °C


FID

-Maximum temperature: 450 °C

-Detectivity: 2 pg C/see

-Linear dynamic range: 107

-Patented ceramic -Flame tip: standard

-Flame-out detection/auto re-ignition: standard


TCD

-Maximum temperature: 450 °C

-Detectivity: 300 pg/sec (C4)

-Linear dynarnic range: 106

-Filament proteefirm: standard

-Automatic bridge balancing: standard

ECD

-Maximum temperature: 450 °C

-Detectivity: 7 fg/sec Lindane

-Linear dynamic range: 104

This refurbished Varian 3800 GC comes with FID, ECD, TCD and also NCT (Methanizer).

It's in great condition, and has been tested

Other machines similar to Varian

1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1