Menu

Drager Oxylog 3000 Plus

Ref : 2557459-14-W
Condition : Used
Manufacturer : Drager
Model : Oxylog 3000 Plus
Year(s) : -
Quantity : 1
Location : Seller or machines location:
MIDDLE EAST

The Drager Oxylog 3000 plus is a transport ventilator
that can provide high ventilation performance.
The Oxylog system includes integrated capnography and non-invasive ventilation.
It runs on a time-cycle that can monitor a wide range of ventilation modes,
including VC-AC, VC-SIMV, San-CPAP, and PC-BiPAP.
The Oxylog 3000 Plus is a non-invasive ventilation machine
with advanced leak composition. the system can be used in a hospital setting,
in the field for emergencies, and can be used in winged aircraft for both adult
and pediatric patients.

Features
High confidence during transport.
Wide range of ventilation modes and AutoFlow.
Integrated capnography.
Ready for pediatric patients.
Automatic altitude compensation (BTPS).
Intuitive user interface.
Advanced data export functionality.

General
Tidal volume: VT 0.05 to 2.0 L; BTPS
Ti / I:E: I:E or Ti configurable, for all ventilation modes
Ventilation Time Tatio I:E: 1:100 to 50:1
Inspiration Time Ti: 0.2 to 10 s
Inspiratory Pressure Pinsp: PEEP +3 to +55 mbar
O2 Concentration: 40 to 100 Vol.%
PEEP / CPAP: 0 to 20 mbar
Trigger Sensitivity (Flow Trigger): 1 to 15 L/min
PressureSsupport ΔPsupp: 0 to 35 mbar (relative to PEEP)
Slope (Pressure Rise Time): Slow, standard, fast

Dimensions
Height: 7.2 In (18.4 cm)
Width: 11.4 In (29 cm)
Depth: 6.9 In (17.5 cm)
Weight (Including internal battery): 12.8 lbs (5.8 kg)

Display
Technology: Electro-luminescence (EL)
Resolution: 240 x 128
Dimensions: 4.3 x 2.2 In (10.8 x 5.6 cm)

Wireless Network
Standards: IEEE 802.11g, Wi-Fi compatible
Frequency Range: 2.412 to 2.462GHz

Ventilation Modes
VC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAP

Ventilation Settings
Pressure support: in the ventilation modes VCSIMV, PCBIPAP and SpnCPAP
Apnoea ventilation: in the ventilation mode SpnCPAP
AutoFlow (optional): in the ventilation modes VC-CMV, VCAC and VC-SIMV
NIV: in the ventilation modes: SpnCPAP (/PS), PC-BIPAP (/PS), VC-CMV /AF, VC-AC /AF and VC-SIMV/AF

Ventilation Respiratory Rate
2 to 60 /min (VC-SIMV, PC-BIPAP)
5 to 60 /min (VC-CMV, VC-AC)
12 to 60 /min for apnoea ventilation

Other machines similar to Drager Oxylog 3000 Plus

1
Location : EUROPE (Western and Northern)
Year(s) : 2003
1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
1