Menu

GE B125 Patient Monitor

Ref : 2539171-14-W
Condition : Used
Manufacturer : GE
Model : B125 Patient Monitor
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

Condition: Certified Refurbished MFI Medical image--4
Warranty: 90 Days
Uninterrupted display of primary ECG-lead waveform and other vital signs across settings
Capacitive touchscreen for fast response and enhanced user experience

Features
Seven pre-configured workflow settings for simple set-up.
Auto-snapshot of most critical alarms.
Alarm reporting options for better alarm management and instant care in cases
of arrhythmia, high/low blood pressure, and ECG-lead detachment.
Convenient screen lock button for easy cleaning, maintenance, and intra-hospital transport.
Capacitive touchscreen for fast response and enhanced user experience.
Uninterrupted display of primary ECG-lead waveform and other vital signs across settings.
Choice of numerical or continuous waveform monitoring.
Large numeric mode that enables critical parameter visibility even up to four meters.


Weight: 25 lb (11.3 kg).
Dimensions: 18" x 18" x 18" (45.7 cm x 45.7 cm x 45.7 cm).

Display:
Size: 12.1" (diagonal).
Resolution: 1280 x 800 pixels (WVGA).
Number of Waveforms: Up to 6.
Display Layout and Colors: User-configurable.
Controls: Capacitive Touch Screen and Trim Knob control and hard keys (standard).

ECG:
Leads Available:
3-Lead Configuration: I, II, III.
5-Lead Configuration: I, II, III, aVR, aVL, aVF, and V.
Sweep Speed: 12.5, 25, or 50 mm/s.
Gain Range: 0.5 x , 1 x, 2 x, and 4 x.
Heart Rate Accuracy: 30 to 300 bpm, +/- 5% or +/-5 bpm, whichever is greater.

50/60 Hz Power Supply:
Monitor: 0.5 to 40 Hz.
ST: 0.05 to 40 Hz.
Diagnostic: 0.05 to 145 Hz.

Pacemaker Detection:
Range: 2 to 700 mV.
Pulse Width: 0.5 to 2 ms.
Arrhythmia Analysis: Asystole, V Fib / V Tach, V Tach, VT>2 R on T, V Brady,
Couplet, Bigeminy, Accelerated Ventricular arrhythmia, Multifocal PVCs,
A Fib, Missing beat, Pause, Tachy, Brady, Trigeminy.

ST Segment Analysis:
Numeric Range: -9 to +9 mm (-0.9 to +0.9 mV).
Accuracy: +/- 0.2 mm or +/- 10%, whichever is greater, within the measurement range of -8 to 8 mm.
Numeric Resolution: 0.1 mm (0.01 mV).
ST Trends: Up to 168h.

Range:
Adult/Pediatric: 4 to 120 resp/min.
Neonate: 4 to 180 resp/min.
Accuracy: +/- 5% or +/- 5 resp/min, whichever is greater.
Gain Range: 0.1 to 5 cm/Ohm.

SpO2:
GE:
Pulse Oximetry Measurement Range: 1 to 100%.
Pulse Rate: 30 to 250 bpm.
Saturation Measurement Accuracy:
Without Motion-Adult/Pediatric Finger Sensor: 70 to 100% +/- 2%
Without Motion-Neonate: 70 to 100% +/- 3%.
With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
Low Perfusion-Adult/Pediatric: 70 to 100% +/-3% (1~69% unspecified).
Pulse Rate: Without Motion: +/- 2 bpm (adult/pediatric/neonatal).

Nellcor:
Pulse Oximetry Measurement Range: 1 to 100%.
Pulse Rate: 20 to 250 bpm.
Saturation Measurement Accuracy:
Adult: 70 to 100% +/- 2%.
Neo: 70 to 100% +/- 3%.
Low Perfusion: 70 to 100% +/- 2%; 0~69% unspecified.
Pulse Rate: +/- 3 bpm.

Masimo:
Pulse Oximetry Measurement Range: 1 to 100%.
Pulse Rate: 25 to 240 bpm.
Saturation Measurement Accuracy:
Without Motion-Adult/Pediatric: 70 to 100% +/- 2%.
Without Motion-Neonate: 70 to 100% +/- 3%.
With Motion-Adult/Pediatric/Neonate: 70 to 100% +/- 3%.
Low Perfusion: 70 to 100% +/-2% (0 to 69% unspecified).

Pulse Rate:
Without Motion: +/- bpm.
With Motion: +/- 5 bpm.

NIBP:
Measurement Technique: Oscillometric with step deflation.
Modes: Manual, Automatic, Stat.
Systolic Measurement Range:
Adult/Pediatric: 30 to 290 mmHg.
Neonate: 30 to 260 mmHg.
MAP Measurement Range:
Adult/Pediatric: 20 to 260 mmHg.
Neonate: 20 to 125 mmHg.
Diastolic Measurement Range:
Adult/Pediatric: 10 to 220 mmHg.
Neonate: 10 to 110 mmHg.
Accuracy: Meets AAMI ISO81060-2 and IEC 80601-2-30.
Default Initial Inflation Pressure:
Adult/Pediatric: 135 +/- 15 mmHg.
Neonate: 100 +/- 15 mmHg.

Maximum Determination Time:
Adult/Pediatric: 2 min.
Neonate: 100 +/- 15 mmHg.

Over Pressure Monitor:
Adult/Pediatric: 294 +/-6 to 330 mmHg.
Neonate: 147 +/- 3 to 165 mmHg.

Invasive Blood Pressure:
Measurement Range: -40 to 320 mmHg (15.3 to 42.7 kPa).
Measurement Accuracy; +/- 5% or +/- 2 mmHg, whichever is greater.
Frequency Response: 4 to 22 Hz.
Transducer Sensitivity: 5 μV/V/mmHg.

Temperature:
Numerical Display: T1, T2, T2-T1.
Measurement Range: 10 to 45 degrees C (50 to 113 degrees F).
Measurement Accuracy: +/- 0.1 degrees C without probe.
Display Resolution: 0.1 degrees C.
Probe: YSI probes recommended by GE Healthcare.

Networking:
Compatibility: CARESCAPE Network.
Wi-Fi Connectivity: IEEE 802.11a/b/g/n.

Wi-Fi Security:
WPA-Personal.
WPA2-Personal.
WPA-Enterprise.
WPA2-Enterprise.

Other machines similar to GE B125 Patient Monitor

1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
Year(s) : 2010
1
Location : EUROPE (Western and Northern)
Year(s) : 2021