Menu

GE Discovery MR750 3T

Ref : 2521766-14-CP
Condition : Used
Manufacturer : GE
Model : Discovery MR750 3T
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

High performance whole-body gradients designed
to deliver powerful 50 mT/m amplitude and 200 T/m/s slew-rate
on each axis simultaneously.
ARC parallel-imaging, which utilizes a full 3D data kernel
for more accurate reconstruction.
A volume-reconstruction engine that enables real-time image generation.
OpTix optical RF technology, engineered to increase signal clarity
and maximize signal intensity.
PERFORM 2.0, which automatically fine-tunes system SAR modelling
and personalizes it for each patient.
The eXtreme resonance module (XRM), which delivers a 48-cm field of view
with linearity.
VIBRANT Flex technology, which combines multiple series of breast scans into one.
Time of Flight (TOF) imaging, which rapidly captures high-definition images
that display small-vessel detail and blood-flow subtleties—without contrast injections.
IntelliTouch patient positioning—start scanning in just two steps.
BrainWave suite of functional MRI (fMRI) applications,
which provide excellent signal stability, and an exceptional signal-to-noise ratio.

Fast Image Acquisition - More Scans in Less Time
Reconditioned to OEM Specs - High Quality at Lower Cost

Benefits:
Technology:
Exceptional homogeneity and image quality across a large 48- x 48- x 48-cm field of view
Faster and more accurate and reproducible scans1
Increased signal clarity and maximized signal intensity for cleaner, crisper images
Better contrast between flowing blood and surrounding tissue
Consistent, uniform fat suppression
Easier neurofunctional brain mapping and DTI

Productivity:
Higher performance with real-time system optimization
Accelerated and accurate parallel imaging
Fewer operating steps, which lead to shorter exam times
Less slowdowns through heat-extraction technology
Faster reconstructions for data-intensive, 32-channel studies
Intuitive, protocol-driven user interface

Comfort:
Fast, automated patient set-up—less than 30 seconds
Quicker patient transfer with a detachable patient table

Specifications:
Wide bore MRI scanner: No
Magnetic field strength, T: 3
Line of sight, cm: 48
MRI Type: closed
Gradient: 50
Type of magnet: superconducting
Gradient slew rate (mТ/m/mcs): 200
Gantry aperture (mm): 600