Menu

Mindray T1 Patient Monitor With Docking Station

Ref : 2626109-14-AW
Condition : Used
Manufacturer : Mindray
Model : T1 Patient Monitor With Docking Station
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

No Cable

The Mindray T1 is a compact,
lightweight transport monitoring solution.
The T1 is a muti-parameter module that
goes further with arrhythmia analysis,
12-lead ECG, Co2 Monitoring,
and integrated wireless Communication.
The T1Is are connected to an external monitor with
a touch screen, and the T1 can be transformed into
a bedside monitor.
With expanded capabilities, built-in screen layouts for
customization of waveforms and numeric data.

Robust monitoring in a compact,
lightweight package
5? brilliant touchscreen display
Familiar intuitive interface across the Passport family
Up to 4 waveforms displayed
Over 10 critical parameters can be monitored
Extensive data storage and up to 48 hours of
full disclosure
Serves as multi-parameter module for
Passport 12m and 17m monitors
Flexible transport solution
Connect to Mindray 19? touchscreen display to
create expanded bedside monitor l
Multiple mounting solutions
Defibrillator synchronization
Wired and wireless communications to central stations; has a 2.4/5GHz dual band radio
Battery run time of over 3.5 hours

Specifications:
Dimensions
Height: 4 in (10.2 cm)
Width: 3.2in (14.2 cm)
Depth: 3.2 in (8.1cm)
Weight: 2 lbs (.9 kg)
Docking Station
USB 2.0 Connectors: 2 (standard)
Network Connector: 1 (RJ45)
Equipotential Grounding Terminal: 1
AC Power Input: 1 (standard 3-pin power connector)
VGA Connector: 1 (standard)
External Device Connector: 1
Multi-pin Connector: 1
Power Requirements
Power Adapter: 100 to 240 VAC, 0.6 to 0.4 A, 50/60Hz, 12VDC 2A
Docking Station: 100 to 240 VAC, 0.65 to 0.35 A, 50/60Hz
Battery
Type: Rechargeable li-ion battery pack
Capacity: 2500 mAh
Number: 1

Run Time: 4 hr when powered by
a new fully-charged battery at 25°C with ECG and
SpO2 cable connected, and auto NIBP measurements at
an interval of 15 minutes.
Battery run time varies as per system configuration and settings.
Charge Time: Charge battery with the patient monitor:
Less than 3 hours to 90% and less than 4 hours to
100% with equipment power off Less than 12 hours to
90% and less than 14 hours to 100% with
equipment power on
Shutdown Delay: At least 20 minutes (after a
low battery alarm first occurs)

Other machines similar to Mindray T1 Patient Monitor With Docking Station

1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
1
Location : EUROPE (Western and Northern)
Year(s) : 2016