Menu

Nidek YC1800 GYC1000 Combo Laser

Ref : 2625740-13-AW
Condition : Used
Manufacturer : Nidek
Model : YC1800 GYC1000 Combo Laser
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

This unit has been completely inspected by our staff,
all optics have been cleaned, software updated,
and a service calibration has been performed.

All functions are working to
the manufacturer’s specifications and
this Combo YAG/Argon is ready for use.

Easily transition from YAG capsulotomies to 532nm Retina wavelength with this all-in-one platform!

YC-1800 Yag Laser:
The YC-1800 offers 0.3 to 10 mJ,
continuously adjustable in increments of 0.1 mJ,
allowing the precise tissue effect.

The dual 635 nm aiming beam offers superior visual sensitivity,
which in turn enhances the speed and ease of operation.
The 635 nm beam is also safer to
human eyes since it achieves the same crisp and
sharp intensity of 650 nm or 670 nm beam with
half the power output.
The YC-1800 has the ability to
rotate the dual aiming beams 360º permitting work
anywhere in the periphery without clipping the iris.

The YC-1800 can adjust the offset between ±500 microns
(25 micron steps) to meet the varied clinical needs.
A different offset can be used for PMMA,
silicone or acrylic lenses, and the offset can even be
adjusted on the same IOL to compensate for
a parallax effect in the periphery.
This eliminates the need to manually defocus,
permits a clear field of view, and reduces lens pitting.

Specifications:
-Type: Nd: YAG
-Wavelength: 1064 nm
-Mode Structure: Fundamental
-Pulse Duration: 4 nsec
-Mode of operation: Q-switched
-Pulse repetition rate: 3 Hz (single) / 1.5 Hz (burst)
-Output energy: 0.3 to 10.0 mJ / pulse (continuously variable)
-Burst mode: 2 or 3 pulse / trigger
-Spot size: 8 μm
-Cone angle: 16º
-Focus Shift: 0 to 500 μm (continuously variable, toward both anterior chamber and Posterior chamber
532nm Green Laser

Efficient, safe photocoagulation is a hallmark of
the GYC- 1000.
The 532nm laser beam passes through the ocular media with
low attenuation to minimize power loss.
– Higher absorption by the pigment epitheliopathy, hemoglobin, and oxidized hemoglobin
– Lower absorption by the xanthophyll pigment

Exposure time of conventional lasers can be adjusted in
0.10 second increments, from 0.10 to 1.00 seconds.
The GYC-1000’s exposure time can be adjusted in
0.05 second increments from 0.10 to 0.50 seconds,
which is the most widely used range for photocoagulation.
The finer adjustments provide more precise treatment for patients.

Specifications:
Treatment Laser: Frequency-Doubled Diode Pumped Solid State Laser
Wavelength: Green: 532nm
Output power: Green: 50-1700mW
Output type: Continuous Wave
Exposure times: 0.01-3.00 seconds
Automation repeat: 0.1-1.0 seconds intervals
Aiming laser: Red Diode
Power supply: 90-264Vac, 50/60Hz, 200VA