Olympus Endoscopy Set (OEV191H, CV-180, CLV-180, UHI-3, SURGIFLOW, OTV-S7, WM-NP1)
EUROPE (Central and Eastern)
Reconditioned (used),
Technical condition: very good,
Visual condition: very good,
Real product photos,
The set includes:
OLMYPUS OEV191H medical monitor:
Japanese production,
Power supply: 230 V,
Frequency: 50/60 Hz,
Power: 125 VA,
The Olympus OEV191H is an HDTV-compatible medical monitor,
Progressive scanning reduces image distortion and flicker,
Anti-reflective coating minimizes light reflection,
Image enhancement function,
19" TFT LCD matrix
Horizontal and vertical viewing angle: 85°,
Resolution: 1280 x 1024 px,
Menu in: English,
Keyboard on the control panel in: English,
It has the following inputs and outputs:
COMPUTER,
VIDEO IN-OUT, Y/C IN-OUT,
REMOTE: REMOTE 1, RS-232C,
RGB/COMPONENT: A (G/Y IN-OUT, B/PB IN-OUT, R/PR IN-OUT, EXT SYNC IN-OUT), B (G/Y IN, B/PB IN, R/PR IN, EXT SYNC IN),
OLYMPUS CV-180 EVIS EXERA II image processor:
Japanese production,
Power supply 230 V,
Frequency 50-60 Hz,
Power 150 VA,
The device has the ability to process images in high resolution HDTV to ensure the best image quality in endoscopy and laparoscopy,
Compatible with EVIS 100/130/140 and EVIS EXERA 160 series endoscopes,
HD/SD SDI output for high quality video transfer,
It has a port for xD memory cards,
Foiled control panel,
OLYMPUS CLV-180 EVIS EXERA II light source:
Production: Japanese,
Power supply 230 V,
Frequency 50-60 Hz,
Power 500 VA,
Adapted to flexible endoscopes,
Main lighting: MD 631 / 300 W xenon bulb,
Emergency lighting: 12V/35W halogen bulb,
Foiled control panel,
Built-in air pump with electronic power control,
OYMPUS OTV-S7PROH-HD-12E Camera Head:
The Olympus OTV - S7 is a camera head that, thanks to the 1080/50i PAL format, provides high resolution and extremely accurate imaging,
Narrow-band imaging (NBI) is an optical image enhancement technology that enhances the visibility of vessels and other tissues on mucosal surfaces. This technology exploits the differences in light absorption and reflection properties of blood and surrounding tissues, facilitating the imaging of capillaries that contrast with the surrounding mucosa.
Magnification: 1.2x,
The image can be enlarged up to 1.5x its original size while maintaining high HD image quality,
It has 3 built-in switches that allow you to program frequently used functions, such as electronic zoom and image capture, for convenient remote control,
Possibility of steam or ethylene oxide sterilization,
The tight housing of the camera head prevents fogging of the lenses after steam sterilization,
Sensor System: Interline Semiconductor CCD Image Sensor,
Focal distance (f): 15.8 – 31.3 mm,
OLYMPUS UHI-3 Insufflator:
UK production,
Power supply: 230 V,
Frequency: 50/60 Hz,
Power: 150 VA,
The Olympus UHI-3 is a high-flow insufflator with a built-in smoke evacuation system ensuring good visibility during surgery,
Specification:
Abdominal pressure can be adjusted in 1 mm Hg increments within the range of 3 - 25 mm Hg,
When the pressure in the abdominal cavity becomes too high, a warning light and alarm are activated and the pinch valve on the suction tube opens automatically to release excess pressure,
Quick response to gas leaks helps return pressure to the programmed level,
Noise is kept low thanks to the solenoid valve opening and closing mechanism,
The large digital display on the front panel makes it easy to monitor the pressure,
Keyboard on the control panel in: English,
Actual and set pressure are displayed simultaneously,
Capacity: 35 L/min,
It has 3 main flow settings :
Low: 0.1 – 1.0 L/min,
Medium: 1.1 - 19 L/min,
High: 20 - 35 L/min,
Possibility of gradual flow regulation in steps of 0.1 L/min in the range of 0.1 – 2.0 L/min, which enables careful control of gas supply,
Equipment:
Cable with CO 2 connector ,
OLYMPUS SURGIFLOW endoscopic flushing pump:
Production: German,
Power supply: 230 V,
Frequency: 50/60 Hz,
OLYMPUS SURGIFLOW ensures a constant flow of fluids through the working channel during surgical and diagnostic procedures,
Characteristics:
Ensures precision and safety of procedures by maintaining a clean operating field,
It enables smooth control of fluid flow, which is crucial during minimally invasive procedures,
It is compatible with OLYMPUS endoscopes and other surgical systems,
Specification:
Flow rate max. 2.5 l/min.,
Pressure: 550 mmHg,
Flow settings on a ten-point scale,
Equipment:
Foot attachment,
Instrumentation placed on the mobile 4-wheeled (2 braking wheels) OLYMPUS WM-NP1 endoscopic trolley:
The Olympus WM-NP1 is a stable and durable trolley designed to carry endoscopes and delicate medical equipment,
It has:
Top tabletop dimensions: 47 x 38 cm,
Lower tabletop dimensions: 47.5 x 56 cm,
2 shelves measuring 40 x 54 cm with manual height adjustment (every 1.5 - 2 cm) using Allen screws,
Handles for easy moving of the stroller,
Electrical installation, 12 power sockets for transported medical equipment,
Product features:
Power switch on the front of the stroller,
The detachable rear wall of the stroller makes cable management easier,
Power cables are aesthetically hidden in the panels on the sides of the trolley,
The corners of the shelves are protected with protective covers, and the edges above the wheels are covered with rubber,
Dimensions:
Total: 65 x 65 x 174 cm,
Weight: 160 KG,
It has a current inspection and is ready to work,
Issued Technical Passport (Service Report) valid for 12 months