Perkin Elmer Clarus 690 2-Kanal FID Gaschromatograph
EUROPE (Western and Northern)
Gas chromatograph with autosampler,
It was always serviced and decommissioned by Perkin Elmer.
Features: 2-channel gas chromatograph,
specially configured for controlling pressure-
and flow-programmed injectors and detectors.
N6650D00 high-performance oven,
230 V, 16 A, 50/60 Hz. Heating rates up to 140 °C/min,
maximum temperature 450 °C,
temperature program with up to 10 program steps,
ballistic oven cooling (from 450 °C to 50 °C in less than 2 minutes),
soft cooling option. N665000A GC base unit.
N66500A0 liquid sample autosampler.
Autosampler with 108 sample positions,
four wash liquids, variable injection rate,
and injection volume from 0.1 µl to 50 µl.
N66510K0 S/S injector with PPC, Channel A.
Split/splitless capillary injector with electronic gas control.
N66520F0 Wide-range FID with PPC, Channel A.
Flame ionization detector with amplifier
and electronic gas control for the detector gases,
including automatic flame ignition.
N665100K S/S injector with PPC, Channel B.
Split/splitless capillary injector with electronic gas control.
N665200F Wide-range FID with PPC, Channel B.
Flame ionization detector with amplifier
and electronic gas control for the detector gases,
including automatic flame ignition.
N66530A0 Integral dotLINK.
Interface for digital connection to a chromatography workstation
or direct connection to a LAN.