Shimadzu GC-2014 GC (SPL) with SFID and PID

Specifications
Column Oven
Temperature range (Ambient + 10°C) ~ 400°C (using liquid CO2 gas*: -50°C ~400°C)
Dimensions 250 (W) × 360 (H) × 175 (D) mm
Oven capacity 15.8L
Temperature accuracy Set value (K) ± 1% (calibration at 0.01°C increments)
Temperature deviation 2°C max. (on 200mm dia. circumference 30mm from rear)
Temperature variation coefficient 0.01°C/°C
Temperature program steps Up to 20 (cooling program possible)
Programmed rate setting range -250°C ~ 250°C/min
Total time for all steps 9999.99 minutes max
Linear heating range 30°C/min up to 150°C
20°C/min up to 250°C
10°C/min up to 380°C
7°C/min up to 400°C (at 25°C ambient temperature)
Cooling rate 300°C ~ 50°C in 6 min max. (at 25°C ambient temperature)
Columns accepted Capillary columns: 2
Packed columns for GC14B: 4 (Glass columns: 2)

Sample Injection Unit
Temperature range Up to 400°C
Heating settings 1°C steps
No. of units installed simultaneously Up to 3 units
Sample injection unit types Dual packed, single packed, split/splitless, direct, direct (AMC)


Carrier Gas Flow Controller
For Packed / Dual
Flow rate setting range 0 ~ 100mL/min
Programmable steps 7
Programmed rate setting range 400 ~ 400mL/min
Correction function Maintains column ¬flow rate during column oven heating
For Capillary Split/Splitless, Direct
(Split/splitless injection mode)
Pressure setting range 0 ~ 970kPa
Programmable steps 7 (pressure-decreasing program possible)
Programmed rate setting range -400 ~ 400kPa/min
Split ratio setting range 0 ~ 9999.9
Total fl¬ow rate setting range 0 ~ 1200mL/min
Correction function Maintains column average linear velocity during column oven heating (for capillary only)
(Pressure mode direct injection)
Pressure setting range 0 ~ 970kPa/min
Programmable steps 7
Programmed rate setting range -400 ~ 400kPa/min
Correction function Maintains column average linear velocity during column oven heating
(Flow-rate mode direct injection)
Flow rate setting range 0 ~ 1200mL/min
Programmable steps 7
Programmed rate setting range -400 ~ 400mL/min
For Single Packed, Direct (AMC)
Flow rate setting range 0~100mL/min
Correction function Maintenance column ¬flow rate during column oven heating

Detectors
Temperature range 400°C max. (FID, TCD, FTD) 350°C max. (ECD, FPD)
Temperature setting 1°C steps
No. of units installed simultaneously Up to 4 units (restricted depending on detector type)
Detector type FID, TCD, ECD, FPD, FTD for capillary/packed
Flame Ionization Detector (FID)
System Dual ¬flow rate differential system
Temperature range 400°C max.
Minimum detected quantity 3pgC/s (dodecane)
Dynamic range 107
Nozzle Quartz glass Standard: for packed, Option: for capillary
Thermal Conductivity Detector (TCD)
System Dual flow rate differential system
Temperature range 400°C max.
Dynamic range 105
Sensitivity 40,000mV • mL/mg (built-in pre-amplifier, with 10 × application)
Electron Capture Detector (ECD)
System Fixed current system using 63Ni370MBq radiation source
Temperature range 400°C max.
Minimum detected quantity 0.1pg/s (γ-BHC)
Dynamic range 104
Flame Photometric Detector (FPD)
Temperature range 350°C max.
Dynamic range P: 104 S: 103
Minimum detected quantity P: 0.5pgP/s (tributyl phosphate)
S: 8pgS/s (dodecane thiol)
Flame Thermionic Detector (FTD) (Two types, one for capillary and one for packed. The speci cation are the same.)
Temperature range 400°C max.
Dynamic range N: 103 P: 103
Minimum detected quantity N: 0.4pgN/s (azobenzene)
P: 0.05pgP/s (malathion)

Shimadzu Gas Chromatograph System High Performance and Expandability Merged at a higher level

High Performance
Improved design and innovative technology for all of our injectors, detectors and flow controllers equal or surpass our GC-2010 the high-end technology leader

Easy Operation
Large LCD, all digital gases control and auto-diagnostics inherited from the GC-
2010 – “The Most advanced, easy-to-use interface".

Flexibility
Use any column types for any analysis. Packed or capillary columns give you
the freedom to choose the best technique for your measurement. Fully integrated multiple valve systems are made simple for optimum performance for SystemGC custom GC products.

This Shimadzu GC-2014 GC with SFID and PID is in great condition.

Other machines similar to Shimadzu