Menu

Siemens Emotion 16 CT-Scanner

Ref : 2784875-14-GO
Condition : Used
Manufacturer : Siemens
Model : Emotion 16 CT-Scanner
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

The Siemens Emotion 16 CT-Scanner offers an affordable CT solution
for high resolution images, a long life cycle, fast patient throughput,
and a wide range of clinical imaging applications.
A refurbished used Siemens Emotion 16 CT will provide your
imaging department with a powerful, cost-effective,
multi-slice CT scanner with a comprehensive range of applications.
The Siemens Emotion 16 features a 70cm aperture, 50cm scan field,
and a patient table with a weight capacity of up 440 lbs (200 kg).

Features
SafeCT Low-dose Solution
16-slice acquisition
Wide range of clinical applications
Fast and efficient with 0.6 second rotation time
Multislice UFC detector
0.75 or 1.5mm slices per rotation in less than 20 seconds
Small diagnostic detail for acquisition
105 millisecond temporal resolution for clear depiction of blood vessels
Scan any anatomy with a single breathhold
Pathology seen from any perspective
Low patient dose

Clinical Applications
Abdominal, Adult Cardiac, Functional Imaging, Pediatrics,
Pelvis, Spinal, Thoracic

Technology
syngo LungCARE CT with NEX (Nodule Enhanced Viewing)
syngo Colonography with PEV (Polyp Enhanced Viewing)

Specifications
Gantry
Gantry Generation: 3rd
Slipring: Low voltage
Aperture: 70 cm
FOV: 50 cm (standard), 70 cm (optional)
Tilt range: ±30 degrees
Type of positioning lights: Laser
Accuracy of positioning lights: ±1 mm
Focus-detector distance: 940 mm

X-Ray Tube
Type/Make: Siemens Dura 422MV Siemens Straton
Focal spot size(s) quoted to (X-RAY TUBE): 0.5 mm x 0.8 mm
IEC 336/93 standard (X-RAY TUBE) 0.7 x 0.8
Settings at which focal spot change automatically; small changes
kW = kV x mA / 1000: up to 28 kW ; large up to 45 kW
Total filtration (inherent + beam shaping filter) at central axis (mm Al equivalent) (X-RAY TUBE) 6.3 (140kV)
Anode heat capacity (MHU): 5
Maximum anode cooling rate (kHU/min): 810
Method of cooling (X-RAY TUBE) Oil to air
Guaranteed tube life: 200,000 scan seconds
Detector type: Solid state (Ultra Fast Ceramic)
Maximum number of simultaneously acquired data sets (no. of slices): 16
Number of detectors per row (Maximum anode cooling rate):
736 (1472 channels)
Number of elements along z-axis (Maximum anode cooling rate): 24
Effective length of each element at isocentre: 16 x 0.6 mm, 8 x 1.2 mm
Total effective length of detector array at isocentre: 19.2 mm
Option for more slices / rotation (Maximum anode cooling rate): Yes

Generator/ Power
X-ray generator: VAC Power Needed
Type: High frequency
Location: Rotation assembly (Composition)
Power rating – kV settings available (Maximum weight allowed on couch):
50, 80, 110, 130 kW
mA range and step size (Weight bearing properties) 20-345(1mA steps)
Maximum mA allowed for each kV (Weight bearing properties) 80 kV:
345 mA

Main Console
Monitor/ Screen Size: 19 inches
Number of monitors at console (functions of each if > 1) (Image monitor)
Up to 6 (shared database)
Image area matrix dimensions: 1024 x 1024
Usual range of CT number displayed (HU) (Image monitor)
(-10,240 to 30,710 if metal implants)
Accuracy of distance measurements in x-y plane:
depends on pixel size (mm)
Weighted CTDI (CTDIw or CTDIvol) displayed on console: Yes
Dose Length Product (DLP) displayed on console (Dose information): Yes
Geometric Efficiency displayed on console when 70% for all collimations
Control methods: Mouse, keyboard

Other machines similar to Siemens Emotion 16 CT-Scanner

1
Location : OCEANIA
Year(s) : 2014
1
Location : OCEANIA
Year(s) : 2015
1
Location : EUROPE (Western and Northern)
Year(s) : 2011
1
Location : EUROPE (Central and Eastern)