Siemens Sensation 64
AMERICA North (USA-Canada-Mexico)
The Siemens SOMATOM Sensation 64 Slice CT is the flagship of
the award-winning Sensation series.
The Siemens Sensation 64 was the first CT scanner with the ability to
take 192 images of the heart per second.
Like the Sensation 40 Slice, the Siemens Sensation 64 slice offers a
very high routine isotropic resolution of 0.33mm, allowing it to
visualize the smalles pathology with outstanding quality.
The z-UHR option on the Siemens Sensation 64 offers an
exceptional 0.24mm isotropic resolution, allowing it to clearly visualize the
complex inner ear bones and joints. Siemens CARE dose reduction is
also featured on the Sensation 64.
Features
0.33mm isotropic resolution (standard)
0.24mm isotropic resolution (with z-UHR option)
Cardiac imaging rotation time of .33 seconds
UDF detector
Spiral artifact-free imaging
STRATON X-ray tube technology
z-Sharp technology
Routine exam detection of soft plaques
70% reduction in radiation dose
Sub-millimeter coverage: 87 mm/s
Data Acquisition (slices/rotation): 64
0 MHU X-Ray tube: STRATON with 5 MHU/min cooling rate
Generator peak power: 80 kW
CARE Dose4D
Specifications
SafeCT Low-dose Solution
Configuration: Multislice helical
# of slices: 64
Power: 380-480 VAC, 3-phase, 63-111 kVA
Siting Requirements: 24 m2 (floor space needed)
X-Ray Tube
X-Ray Tube Anode
Heat storage, hu (X-ray tube anode) 0.6 MHU with 5 MHU/ min heat dissipation
Heat dissipation rate, hu/min (X-RAY TUBE) 5,0,000
Tube cooling (X-ray tube anode) Chilled water
Tube focal spot, mm (X-ray tube anode) 0.6 x 0.7, 0.8 x 0.8, 0.8 x 1.2
Image Processing
CPU: Multiple Intel-based servers with Dual Pentium Xenon
Scan fovs: 50 cm (Standard); 70 cm (Optional)
Image reconstruction matrixes: 512 x 512
DICOM 3.0 Compatible (Power Needed, VAC) Yes
Reconstruction time
Per slice, sec (Reconstruction time) 0.06
For localization scan, sec (Reconstruction time) Real time
Display
Helical Scanning: Yes
Max scan time: 100 seconds
Max scan volume: 157 cm
Spatial resolution: 30 lp/cm
Pitch: 28.2-128 freely selectable
Reconstruction time per image: 0.06 seconds
Monitor: 18 inch LCD
Matrixes: 1024 x 1024
Range of ct numbers: -1,024 to +3,071
Image enlarging scale: Yes
Max # slices displayed simultaneously: 64 slices
Image storage
Hd capacity: 446 Gigabytes
No. online images: 260000
Archive: CD-R, MOD
Scoring of Coronary Artery Calcification: Yes
Performance
Minimum interscan time: 0.25 seconds
High-contrast spatial resolution 0% mtf: 30 lp/cm
50% mtf, lp/cm (PERFORMANCE) 15
Low-contrast resolution, mm at % at