Menu

ZEISS Cirrus 500 HD OCT

Ref : 2759131-13
Condition : Used
Manufacturer : ZEISS
Model : Cirrus 500 HD OCT
Year(s) : -
Quantity : 1
Location : Seller or machines location:
ASIA (South East)

Zeiss Cirrus 500 HD-OCT for Sale, Patient-Ready Optical Coherence Tomography System,
has been fully refurbished by Zeiss certified Technicians and
comes with a 12-month parts and service warranty.
This refurbished Zeiss Cirrus 500 HD-OCT offers the same reliability and precision as
a new system, at a fraction of the cost. Each device is fully serviced, calibrated,
and quality checked to meet clinical performance standards ready to use the moment it
arrives at your practice. Every refurbished Zeiss Cirrus 500 OCT undergoes a
strict multi-point inspection by certified biomedical engineers.

We ensure:
100% functional verification of all hardware and optics
Calibration to manufacturer standards
Software reinstallation and performance optimization
Replacement of worn parts with OEM components
Thorough cleaning and cosmetic restoration
Final image quality and safety testing
Included
Refurbished Zeiss Cirrus 500 HD-OCT
Computer with pre-installed Zeiss software
LCD monitor, keyboard, and mouse
Power cables and accessories
User manual
6 month warranty and technical support
30 days money back guarantee

Zeiss Cirrus 500 HD-OCT – High-Definition Optical Coherence Tomography System
The Zeiss Cirrus 500 HD-OCT is a high-performance Optical Coherence Tomography
(OCT) system engineered for retinal, macular, and optic-nerve head imaging. Developed
by Carl Zeiss Meditec, a global leader in ophthalmic diagnostics,
the Cirrus 500 delivers exceptional image clarity, reproducibility,
and workflow efficiency empowering eye-care professionals to detect,
diagnose, and monitor ocular diseases with precision and confidence.

Designed for clinical reliability and ease of use, the Cirrus 500 integrates advanced
scanning optics, sophisticated analysis software, and a compact footprint ideal for
ophthalmology clinics, hospitals, and optometry practices.

The Zeiss Cirrus 500 HD-OCT is one of the most widely used OCT systems in
ophthalmology and optometry. It delivers clear, detailed retinal images for
accurate diagnosis and patient monitoring.

The Zeiss Cirrus 500 HD-OCT is a trusted imaging system designed for
high-definition retinal and optic nerve analysis.

Key Features & Benefits
High-Definition Imaging
Captures ultra-high-resolution retinal cross-sections with axial resolution around
5 microns, enabling detailed visualization of retinal layers.
Provides both qualitative and quantitative analysis for accurate diagnosis of
retinal pathologies.

Fast Scanning Performance
Scan speed of 27,000 A-scans per second reduces motion artifacts and
enhances patient comfort.
Multiple scan patterns (Macula Cube 512×128, Optic Disc Cube 200×200,
Radial Line, Raster Line) deliver comprehensive coverage in seconds.

Advanced Analysis Software
Automated segmentation of retinal layers for precise thickness maps.
Glaucoma and macular progression analysis modules with normative databases.
DICOM-compatible for seamless integration with EMR systems.
Intuitive user interface simplifies exam setup, image review, and report generation.

IIntegrated Data Management
Built-in Cirrus Review Software allows clinicians to view and
analyze patient data anywhere in the clinic.
Long-term data storage supports trend analysis for disease progression and
treatment outcomes.
Compact & Ergonomic Design

All-in-one tabletop configuration with minimal footprint.
Operator-friendly joystick and patient alignment system ensure quick,
comfortable examinations.

Reliable Zeiss Quality
Engineered with durable components and precision optics.
Known for longevity, minimal maintenance, and consistent imaging performance.

The Zeiss Cirrus 500 HD-OCT supports a wide range of ophthalmic diagnostic applications:
Glaucoma detection and monitoring (optic-nerve and RNFL analysis)
Macular degeneration evaluation (AMD, CNV, drusen)
Diabetic retinopathy and macular edema assessment
Retinal-layer mapping and vitreoretinal interface analysis
Pre-and post-surgical evaluation of retinal and optic-nerve conditions

OCT Imaging:
Methodology: Spectral domain OCT
Optical source: Superluminescent diode (SLD), 840 nm
Scan speed: 27K- 68K A-scans per second
A-scan: 2.0 mm (in tissue), 1024
Axial resolution: 5 μm (in tissue)
Transverse resolution: 15 μm (in tissue)

Fundus Imaging:
Methodology: Love OCT Fundus
Live fundus image: During alignment
Optical source: Superluminescent diode (SLD), 840 nm
Field of view: 36 degrees W x 30 degrees H
Frame rate: > 1.7 Hz
Transverse resolution: 45 μm (in tissue)

Iris Imaging:
Methodology: CCD camera
Resolution: 1280 x 1024
Live iris image: During alignment

Electrical and Physical:
Weight: 76 lbs (34 kg)
Dimensions of instrument: 26L x 18W x 21H (in), 65L x 46W x 53H (cm)
Dimensions of table: 39L x 22W (in), 99L x 56W (cm)
Fixation: Internal, external
Internal fixation focus adjustment: -20D to +20D (diopters)
Electrical rating (115V): Single Phase, 100–120V~ systems: 50/60Hz, 5A
Electrical rating (230V): Single Phase, 220–240V~ systems: 50/60Hz, 2.5A

Internal Computer:
Operating system/processor: Windows 7, 4th generation i7 Intel processor
Memory: 16 GB
Hard drive/internal storage: ≥ 2 T (> 200,000 scans)
Display: Integrated 19“ color flat panel display
USB ports: 6 ports

Parameter Specification
Technology Spectral-domain OCT
Axial Resolution ~5 μm
Transverse Resolution ~15–20 μm
Scan Speed 27,000 A-scans/second
Scan Depth 2.0 mm in tissue
Scan Patterns Macula Cube 512×128, Optic Disc Cube 200×200, Line Raster, Radial, 3D Cube
Field of View 6 mm × 6 mm
Display Integrated LCD monitor
Connectivity USB / DICOM / Network
Power 100–240 V AC, 50–60 Hz
Dimensions Approx. 19 in (W) × 18 in (D) × 16 in (H)
Weight ~50 lbs (23 kg)

Other machines similar to ZEISS Cirrus 500 HD OCT

1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : EUROPE (Western and Northern)
Year(s) : 2017