Menu

Used IR Spectrometers and others type

97 results
0

Working range from 350 cm-1 to 7800 cm-1. USB interface. Laser class 1. 230 V. 50/60 Hz. 150 W. Location : EUROPE (Western and Northern)

Price : On request

More details  
0

With pressure accumulator. Capacity: 10L Maximum 20 bar. Accessories: hose connections, small parts. 230 V. 50 Location : EUROPE (Western and Northern)

Price : On request

More details  
0

Analyzer with manual pipetting. For ethanol, pH, sugar and organic acids. Analysis time: 30 seconds. Sample te Year(s) : 2018 Location : EUROPE (Western and Northern)

Price : On request

More details  
0

With Platinum ATR unit. Laser class I. Multi-cuvette slot for round and rectangular cuvettes, Ø approx. 16 mm. Location : EUROPE (Western and Northern)

Price : On request

More details  
0

with SpectrAA v5.2 PC workstation OPTIONAL: Varian VGA77 vapor generator (VGA-77) & Agilent mercury lamp (p/n Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

complete with chiller, autosampler and PC workstation Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

OPTIONAL: Agilent GTA 120 Graphite Tube Atomizer (p/n AA1105M547) & Agilent Technologies PSD 120 Programmable Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
0

Refurbished Shimadzu AA-7000 double beam Atomic Absorption Spectrophotometer Complete with Shimadzu WizAArd 5 Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
0

FEATURES Wave number range 4000 to 600 cm EZ-scan software for instrument control and data acquisition 2 cm-1 Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
0

mass spectrometer complete with Turbo V-Source with ESI Probe, Varian Vacuum Pump with hose custom bench on wh Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
0

complete with THGA-700 transverse heated graphite atomizer Perkin Elmer furnace cooling system (p/n 198072) an Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

<b> 1x Thermo-Nicolet, AVATAR 380, FT-IR Spectrometer Description </b> A nice FT-IR spectrometer for R&D Res Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

<b> 1x Thermo-Nicolet, AVATAR 370, FT-IR Spectrometer Description </b> A Mid-IR spectrometer for routine-us Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

<b> 1x Thermo-Nicolet, AVATAR 380, 370 w/ Smart OMNI-Sampler Description </b> A Mid-IR spectrometer for rout Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

<b> 1x FOSS, Process Analytics 6500, On-Line NIR Spectrophotometer Description </b> This FOSS Process Analyt Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  
1

Light Source: Tungsten Halogen Spectral Bandwidth: 4nm Wavelength Range: 320-1100nm Specifications Stray light Location : EUROPE (Western and Northern)

Price : On request

More details  
1

Brand: Fisons 771 Kevex EDX-771 X-Ray Spectrometer System 9416 Price: $10,500.00 Fisons 771 Kevex EDX-771 Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  

Price On request

More details
1

Brand: Hitachi U-4001 Spectrophotometer Model #: U-4001 This is Hitachi U-4001 Spectrophotometer. This unit Location : AMERICA North (USA-Canada-Mexico)

Price : On request

More details  

Price On request

More details
1

Location : EUROPE (Western and Northern)

Price : On request

More details  
0

With cover. Plug. Software minispec CD for Windows 7. Location : EUROPE (Western and Northern)

Price : On request

More details  
0

With 2x contact measuring heads PSS-H-B01. Optical fiber PSS-F, fiber length 1x 0.5m and 1x 30m with a spectra Year(s) : 2019 Location : EUROPE (Western and Northern)

Price : On request

More details  
0

Combines the precision of polarization FT technology with the cleanliness requirements in the production envi Year(s) : 2017 Location : EUROPE (Western and Northern)

Price : On request

More details  
0

With Omnic Spectra Softre. Sample holder and lid for transfer. New laser installed in 2022. Location : EUROPE (Western and Northern)

Price : On request

More details  

You can find used IR Spectrometers and others type on Wotol

The main manufacturers of IR Spectrometers and others type are Perkin Elmer, Thermo Nicolet, Jasco, Foss, Nicolet, Bruker, Shimadzu, Thermo Electron, Varian, Agilent, Thermo, Alere, Magna.

Find the right Spectrophotometer or Instrumental color measurement with our expert
This instrument has lens, light source, difraction gratting or prism and color analyser.
What is "Color" ? When we see the object and then we say the color is Blue , do you know why ?
It is because object reflected Blue color and adsorb other color. To see colors we need: Object, illuminant (light source), observer (Eyes or Lens) and then Brain or Analyser will calculate so we have "Color"
Our eyes always see what refelected by object. Similar case with Spectrophotometer it can measure reflectance and transmitance.
The next step would be the physical measurement of  the
object, for reflected (or transmitted) light, by a color spectrophotometer.  The basic information provide by  the “spectro” is simply the wavelength reflectance values across the visible spectrum, known as spectral data, which can be displayed as a spectral curve.

Now 2 of the 3 elements  of the observer situation are represented as numbers.
Spectral reflectance data
- Spectral measurement range:
  380nm to 730nm
- Reflectance range
  "Normal" samples: 0% to 100%
  (100% = perfect white diffusor  0% = perfect black)
  Effect samples: up to 300% (for small aspecular angles)
  Fluorescent colors: up to 200%

Color identification
Spectral information under defined geometrical conditions is the fingerprint of a color
The spectral information can be transformed so that colors can be arranged in a 3 - dimensional color space
Every color has a unique "address" color space
The "address" is valid for a certain illuminant (D65 or A or TL84 or others) and  for a certain observer (2° or 10°) and for a certain geometry (d/8°, 45°/0° or others) !
Changing illuminant and/or observer and/or geometry in most cases will result in a different "address" in color space for the same sample
Color order system, color space
CIE L*a*b*   1976
Based on the Munsell system
L* a* b* are the primary coordinates
L*:   Lightness direction
a*:   red - green direction
b*:   yellow - blue direction
CIE Lab system is industry standard

CIE Lab system version 2
C*, h: Same facts, different description
polar coordinates instead of kartesian coordinates
Chroma     (independent of hue)
C*= (a*2 + b*2) 1/2
Hue angle (independent of chroma)
h= arctan (b* / a*) counterclockwise, starting at positive a* axis with h = 0°

Color difference description
Most important for industrial use
Color difference is the distance in color space between two adresses", e.g. between the "adress" of a standard and the "adress" of a trial.
The color difference has 3 components:
Lightness difference     dL*=L*trial - L*standard
red-green difference     da*=a*trial - a*standard
yellow-blue difference   db*=b*trial - b*standard

Total color difference dE* is calculated from the 3 components:
dE*= (dL*2 + da*2 + db*2) 1/2
Same facts, different description
dE*= (dL*2 + dC*2 + dH*2) 1/2
Chroma difference     dC* = C*trial - C*standard
Hue difference   dH*= (da*2 + db*2 - dC*2) 1/2
sign dH*: positive if
a*trial  b*standard - a*standard b*trial R0 else negative.

Attention: dH* is a distance in color space and not the difference of the hue angles htrial - hstandard !!!
But the computer has no problem with the slightly complicated calculation

Common brand:
Datacolor, GretagMacbeth, Hunterlab, Kurabo, Macbeth, Minolta and Xrite

Create an alert
});