Agilent 1100 HPLC G1389A MicroALS Autosampler

Ref : 2326802-18-CP
Condition : Used
Manufacturer : Agilent
Model : 1100
Short Description : HPLC G1389A MicroALS Autosampler
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)
Last check : 15 Jul. 2022

The Agilent 1100 Series Thermostatted Micro Autosampler has a settable injection volume allowing for 0.01 to 8 µl
with a small loop capillary and 0.01 to 40 µl with an extended loop capillary.
There is a precision of < 0.5 % RSD from 5 to 40 µl, < 1 % RSD from 1 to 5 µl, and < 3 % RSD from 0.2 to 1 µl.
The G1389A features a Thermostattable Tray for 100 x 2 ml vials and can be used with microvials (100 or 300 µl) with sleeves.
It has early maintenance feedback (EMF) and electronic records of maintenance and errors.
Safety features include a leak detection and safe leak handling, low voltages in maintenance areas, and error detection and display.

Specifications :
Weight : 14.2 kg (31.3 lbs)
Dimensions (H x W x D) : 200 x 345 x 435 mm (8 x 13.5 x 17 in)
Line Voltage : 100 – 120 or 220 – 240 VAC, ± 10 %
Line frequency : 50 or 60 Hz, ± 5 %
Power consumption (apparent power) : 300 VA max.
Power consumption (active power) : 200 W max.

Ambient operating temperature : 4 – 55 °C (41 – 131 °F)
Ambient non-operating temperature : 40 to 70 °C (-4 to 158 °F)
Humidity : < 95 %, at 25 – 40 °C (77 – 104 °F) non-condensing
Tray : Thermostattable Tray for 100 x 2 ml vials Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)
Settable injection volume :
0.01 to 8 µl with small loop capillary
0.01 to 40 µl with extended loop capillary
Precision : Typically < 0.5 % RSD from 5 to 40 µl Typically < 1 % RSD from 1 to 5 µl Typically < 3 % RSD from 0.2 to 1 µl
Minimum sample volume : 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials
Carryover : Typically < 0.1 % without automated needle wash Typically < 0.05 % with external needle cleaning and 1 µl injection volume
Sample viscosity range : 0.2 - 5 cp
Recommended pH-range : 1.0 - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries

Material in contact with solvent : Stainless steel, sapphire, PTFE, PEEK, fused silica, Vespel
GLP features : Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications :
Controller-area network (CAN), GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Housing : All materials are recyclable