Harro Hofliger HH-4426.001
EUROPE (Western and Northern)
MACHINE CHARACTERISTICS
PLC: ELAU PacDrive MC-4
Working air temperature: 15 - 25°C
Working humidity: 30 - 70%
Standard according to EN 60204-1
MANUFACTURING CHARACTERISTICS
Output: up to 400 syringes/h (depending on loading, quality, quantity, maintenance, and environment conditions)
Packaged item dimensions: Length 72.5 mm, Diameter 9.4 mm, Volume 1 ml
Packaged item holder: Nest 100
ENERGY CONSUMPTION
Sound power level: Lw S 70 dB(A)
Rated voltage: AC 400/230 V, 3/N/PE
Control voltage: 24 V DC
Current consumption: 7 A
Rated power: 2.4 kVA
Line frequency: 50 Hz
Line configuration: TN
Pneumatic Working pressure: 6 bar
Air type: oil-free
Air consumption: approx. 70 NU per minute
SIZE
Dimension: 1,300 x 850 x 1,900 mm (ca)
Weight: 450 kg (ca)