Philips Allura Xper FD10 Cath/Angio

Ref : 2520946-14-AW
Condition : Used
Manufacturer : Philips
Model : Allura Xper FD10 Cath/Angio
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

Specifications:
Gantry:
Suitable for minimum ceiling heights of 240 cm (94.5 in)
Depth of G-arm: 105 cm (41.3 in)
Ultra-flexible projection angles: angulation from 45° cranial to 45° caudal,
rotation from 120° LAO to 120° RAO
Motorized rotation speed: maximum speed up to 25°/second
Motorized angulation speed: maximum speed up to 18°/second with variable speed,
configurable via Xper settings
Storage and recall of two scratch positions
Isocenter to floor distance: 106.5 cm (41.9 in)
Focal spot to isocenter distance: 76.5 cm (30.1 in)
Focal spot to flat detector distance: 86.5 to 123 cm (34.1 to 48.4 in).
The detector can be positioned manually or via motorized movement
The gantry can be rotated for parking to provide system-free patient accessibility:
can be moved motorized at a speed of 12°/second, automatic snap positions at -90°,
0°, and 90°
The system is delivered standard with two black and white 18-inch LCD monitors
in the examination room
One 19-inch LCD color monitor and one 18-inch black and white LCD monitor
are standard in the control room

XPer Table:
Radio translucent carbon fiber tabletop
Tabletop length: 319 cm (125.5 in)
Tabletop width: 50 cm (19.6 in)
Motorized height movement: 79 - 107 cm (31 - 42 in)
Tabletop metal free overhang: 125 cm (49 in)
Free float at 0 degrees tilt
Longitudinal float: 120 cm (47 in)
Transversal float: 36 cm (14 in)
Maximum allowable patient weight: 250 kg (550 lb) with additional force of 500 N
(100 kg / 220 lb) allowed in case of CPR. CPR can be performed while the tabletop
is set in any longitudinal position
Comfortable patient mattress
The Xper Module, Xper Imaging, and Xper Geometry Modules can be positioned
on three sides of the patient support
Cables incorporated in the table to allow maximum operational flexibility
Table position coordinates
Maximum tilt range: -17° (head-down) to +17° (head-up)
Tilt speed: 2 degrees/second
Isocentric cradle
Maximum cradle range: -15° to +15° for the full tilt range
Cradle speed: 3 degrees/second
Pivot range moves from -90° to +180° (or -180° to +90°) with locked positions
at 0°, -13°, and +31° (to facilitate arm angiography) and -90°, +90°, and 180°

Monitor Ceiling Suspension:
Monitors rotate freely on the high ceiling suspension over a range of 350°
Suspension moves transversely over a distance of 300 cm (118.1 in)
and longitudinally over a distance of 330 cm (129.9 in)
Allows motorized height adjustment over a maximum range of 32 cm

Flat Panel Detector:
Size of detector housing, including BodyGuard: 37 cm (14 in) diagonal
Field of view: 25 cm (10 in), diagonal square
Detector zoom fields: 19 and 15 cm (8 and 6 in) diagonal square format
Pixel size: 184 x 184 microns to allow visualization of the smallest details
Detective Quantum Efficiency DQE (0): 75%
Output digital video frame: 1024² at 14-bit depth resolution
Acquisition speeds can not be customized per system: 3.75, 7.5, 15 and 30 frames/second
Digital video frame out of archiving purposes is customizable via Xper settings
in different formats: 1024², 512², 8 or 10 bit

Velara X-ray Generator:
Microprocessor-controlled, 100 kW high-frequency converter generator
Quartz-controlled IGBT power switch, with a minimum switching time of 1 ms
Voltage range: 40 to 125 kV
Maximum current: 1250 mA at 80 kV
Maximum continuous power: 2.5 kW for 0.5 hours, 2 kW for 0.8 hours
Nominal power (highest electrical power): 100 kW (1000 mA at 100 kV)

MRC-GS 0508 X-ray Tube:
0.5/0.8 nominal focal spot values with maximum loadability of 45 kW and 85 kW
Grid switching with pulsed fluoroscopy
Anode heat dissipation in continuous mode: 3200 W
Fluoro power for 10 minutes: 4500 W
Fluoro power for 20 minutes: 3500 W
Maximum heat dissipation of assembly: 3500 W
SpectraBeam dose management
Oil-cooled X-ray tube with thermal safety switch

Color LCD Monitor:
19-inch color LCD display
Native format: 1280 x 1024 SXGA
Wide viewing angle: approximately 170°
Controlled brightness: typically 270 Cd/ m², with ambient light dependent brightness control
On-screen display of control functions operated via push buttons
Audio output 0.5 watt
Contrast typically 800 on 1

Monochrome LCD Monitor:
18-inch monochrome LCD display with a native format of 1280 x 1024 SXGA
10 bit gray-scale resolution with gray-scale correction
Wide viewing angle: approximately 160°
High brightness: maximum 600 Cd/m², with ambient light dependent brightness control
On-screen display of control functions operated via push buttons
Examination room LCD monitors include protection screen and motorized height adjustment